BCFQP - E-312, PART B HARDENER (DEH24)

Product Identification

Product ID:E-312, PART B HARDENER (DEH24)
MSDS Date:01/01/1985
FSC:8040
NIIN:00N000513
MSDS Number: BCFQP

Responsible Party
BROWN BOVERI ELECTRIC INC.(DIST),DOW CHEMICAL(MFR)

Emergency Phone: 516-636-4400

Cage: 4U971

Contractor
PIEDMONT DIELECTRICS CORP
729 WOODRUFF, SC 29388 US

Telephone: 803-476-8141

Cage: 4U971

Ingredients

ETHYLENEAMINES PERCENT IS A MINIMUM

Fraction By Weight: 99%

Hazards

Effects of Overexposure:MAY CAUSE BURNS OF MOUTH/STOMACH. EYE: SEVERE
BURN. SKIN: SHORT EXP, MILD IRRIT; PROLNGED, SEV BURN.

First Aid

First Aid:SKIN: FLUSH W/WATER 15 MIN, CALL MD. EYE: IMMED FLUSH W/WATER
AT LEAST 30 MIN, CALL MD. INGEST: DO NOT INDUCE VOMIT. GIVE LG AMTS
MILK, TRANSPORT TO MED FACILITY.

Fire Fighting

Flash Point:118C ASTMD93-71
Lower Limits:1.0
Upper Limits:3.6
Extinguishing Media:WATER FOG,ALCOHOL FOAM,CO*2,DRY CHEMICAL
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS & FULL
PROTECTIVE CLOTHES
Unusual Fire/Explosion Hazard:CAN IGNITE IN AIR AT APPROXIMATELY 294C.

Accidental Release

Spill Release Procedures:LG SPILL: DILUTE IMMED W/COPIOUS QTY WATER. SM
SPILL: ABSORB W/APPROPRIATE AGENT SUCH AS SAND.

Handling

Handling and Storage Precautions:PREVENT ALL SKIN/EYE CNTCT. DO NOT
BREATHE VAPORS IF GENERATED. PROD SHOULD NOT CNTCT COPPER OR COPPER
ALLOYS.

Exposure Controls

Ventilation:MECH, SUFFICIENT TO CONTROL COMFORT LEVEL
Protective Gloves:YES
Eye Protection:CHEM WORKERS GOGGLES
Other Protective Equipment:FULL RUBBER PROT CLOTHING INCL BOOTS TO
PREVENT CNTCT
Supplemental Safety and Health
PHYSICAL DATA ARE TYPICAL VALUES. SPECIFIC GRAVITY IS GIVEN @ 25C.
VAPOR PRESSURE: <1 MMHG.FLAMMABLE LIMITS ARE GIVEN @ STP IN AIR @
180C. LD50 (RATS):2460 MG/KG.

Chemical Properties

Boiling Pt:B.P. Text:260 TO 29OC
Spec Gravity:0.977
Solubility in Water:COMPLETE
Appearance and Odor:LIGHT STRAW COLORED LIQUID-AMINE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
ACID, OXIDIZING MATL, COPPER CHLORINATED ORGANIC CMPDS

Disposal

Waste Disposal Methods:MFR SUGGESTS DISPOSAL IN APPRVD LANDFILL

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.